Innovative structure
Modular Design
◆ The overall structure is compact, moreaesthetically pleasing.
◆ With integration feature,it can be installed much more easier.
◆ Increase or decrease function flexibly
Double insulated
◆ Shell using flame retardant insulated material
◆ Fully enclosed design, safer operation
Improved performance
Isolated function
◆ Lock and break (off) position
◆ Reliable machinery atresia
◆ Impulse withstand voltage
◆ Under 1.05 Ue, current leakage is less than 2 m A
Lock and break position
◆ When repairing products or replacing equipments,or under other emergent conditions,HYCQ5P-63 can be locked in off position.
Fast conversion
◆ Minimum conversion time :1.2~1.5 seconds
◆ More suitable for important load
Convenient wiring
Lines get in in main circuit
◆ The primary circuit get the wires in the left and right side, which is in accordance with the traditional habits of wiring.
◆ Main circuit adopt direct pressure way to wire,which is more convenient.
Connected load
◆ Load can be directly connected to outlet end.
Reduce installation space, and the whole set is more beautiful.
◆ Users have no need to do extra wiring, saving installation costs.
Secondary connection
◆ Power supply circuit signal sampling line internal connected
◆ Second l ine adopted plug t ype terminal, which is much more simple and reliable.
Standard and selection
meet the following standard
◆ IEC 60947-1
◆ IEC 60947-2
◆ IEC 60947-6-1
◆ GB14048.1 general rules
◆ GB14048.2 circuit breaker
◆ GB10448.11 automatic transfer switch
Ambient temperature
◆ -25℃~70℃ Operat ing Ambient Temperature Range
When the temperature is above 40℃(motor protection is higher than 65℃) the drop capacity should be considered.
◆ work under normal environment in long term work under - 25 ~ 35or more bad environment
Resistance to hot and humid measures
HYCQ5PA-63 Switch have passed following the strict stipulated conditions test
◆ dry cold climate(-25C)
◆ dry cold climate(+70C)
◆ when it is in 45C,it can be used in environment of 95% relative humidity
◆ when it is in 55C,it can be used in environment of 80% relative humidity
Protection and Category
◆ Protection grade: IP20
◆ Utilization Category: AC-33B

EMC electromagnetic compatibility
◆ Automatic transfer switch can be resisted
◆ Electrostatic discharge (IEC 61000-4-2) level 2
◆ Electromagnetic compatibility Radiated, radio- frequency field immunity
(IEC 61000-4-3) level 3
◆ Electrical fast transient burst (IEC 61000-4-4) level 3 Wave shock (IEC
61000-4-4) level 2
◆ Radio frequency electromagnetic field conducting immunity
(IEC 61000-4-2) level 2
◆ Radiation classes(CISPR11) B class
Model meaning and its classification

Attention:
Controller type :
A terminal type (only has the function of under pressure lose phase protection )
B basic type (phase failure, loss of pressure, overpressure, under voltage and generator start function)
Rated operational current :1.2.4.6.10.16.20.32.40.50.63
Electrical category: CB - have the function of short circuit and overload
Operation mode: R-auto-switch-in, auto-restoring
S-auto-switch-in, without auto-restoring
I-standby for each other
Size and connection
HYCQ5P-63series outline

Functional feature
Performance parameters

Attention:(*)Rated working voltage:1、2、4、6、10、16、20、25、32、40、50、63
■ Standard configuration - without this feature