Automatic switch apparatus is consisted of switch apparatus and the control apparatus.It is mainly applied for monitoring power circuit. It may automatically switch to the spare power supply in case of power failure, realizing the shift between the two different sources power supply.
Pressently, automatic switch apparatus is mainly used in important places such as grade I and grade II power consumption in some buildings, extinguisher, emergency lighting,and automatic power switch in somer infrastructure.
GLOQ1(G) series automatic switch apparatus is a product developed by SIQI Elecrtic Co., Ltd. with self-owned patent technolgy. It is widely used in such distribution system as power consumption under AC 380 50Hz and rated current of 32~400A. In addition, it also may be used for occasional connection, breaker, and circuit isolation.
GLOQ1(G) series automatic switch apparatus has the advantages of high capacity in power load, connection, switch, and anti-inter ference, multi-control, noise-free, and reliable performance.
GLOQ1(G) optimized cosmetic
◆ Four dimensions
◆ Compact and flexible
◆ Decent interface
◆ Convenient and reliable operation
Typical application
GLOQ1(G)400 Low voltage lead line and main distribution disk |
GLOQ1(G)125~320 Distribution disk |
GLOQ1(G)32~100 Load side |

Standards and selectoom
◆ Standards
GLOQ1(G) automatic switch apparatus conforms to the following standards and codes:
GB/T 14048.1 GB/T 14048.3 GB/T 14048.11 IEC60947-1 IEC60947-3 IEC60947-6-1 |
General propositions Low voltage switch, isolation switch, and circuit breaker apparatus Automatic switch apparatus General propositions Low voltage switch, isolation switch, and circuit breaker apparatus Automatic switch apparatus |
◆ Pollution grade
GLOQ1(G) series products may work in an environment with grade III pollution.
The pollution grade can be determined as specified in GB/T14048.
◆ Working conditions
GLOQ1(G) series products may work in an environment with temperature from -5 to 40 degree.
The installation latitude shall be lower than 2000m.
At the highest temperature of +40 degree, the relative humidity of the air shall be lower than 50%.
At lower temperature, higher relative humidity is allowed, for example 90% at 20 degree.
◆ EMC electromagnetic compatibility
GLOQ1(G) automatic switch apparatus passed IEC61000-4 electromagnetic compatibilit test.
◆ Selection


Note: Type A with auto input and recover
Rated working current:32A, 63A, 100A, 125A, 160A, 200A, 250A, 320A, 400A
Function features(Performance indices)

Note: Switch time varies from 1.5 to 3 seconds according to the rated current.
Control function

GLOQ1(G) automatic switch apparatus has three control types
◆ A type
It is mainly for daily power supply, suitable for two power supply circuit, spare system. It may actualize the spare power supply in case of main power failure and the switch will automatically supply the power.
◆ B type
It is mainly for daily power supply, suitable for two power supply circuit, spare system.It may actualize the spare power supply in case of main power insufficiency (delay adjustable) and the switch will automatically supply the power. When the main power restores, it may resume the main power (delay adjustable). The controller has auto input without recover and mutual support.
◆ C type
It is mainly for daily power supply and generator circuit. The generator is the spare power circuit. It may actualize the spare power supply in case of main power failure and insufficiency and the generator will start working. When the main power restores, it may resume the main power and send the signal to the Generator.
Controller
Function description

Dimensions and connections

GLOQ1(G)-32 GLOQ1(G)-63 GLOQ1(G)-100 GLOQ1(G)-125 GLOQ1(G)-160 GLOQ1(G)-200 GLOQ1(G)-250
Electric connection
Main circuit connection

Secondary circuit connection
◆ Secondary circuit connection
Use and maintenance
Cautions
Please indicate the type, specifications, and quantity when ordering, such as working conditions and technical requirements. Please consult us for the information.
◆ Please read through the manual before application and pay attention to:
◇ GLOQ1(G) automatic switch apparatus may work reliably of 85%-110% rated working voltage.
◇ Please pay attention to the lead and out cable (3-phase products requires neutral cable) in application of GLOQ1(G) automatic
switch apparatus. 4-phase products dose not allow public neutral cable and please confirm the earthing.
◇ Please check reagularly (for example once every three months) and check the operation with the test button, manual or auto switch
power.